Voyant Vessel Sealer Set-Up Guide

If you need to print this PDF or save for later
click below to download your copy.

Download PDF

We are happy to provide virtual support during your first case via FaceTime. Please text us to confirm we will be available during your procedure. Call when you are ready to use the Voyant vessel sealer.
Please review the following 3-4 min videos for an overview:

 

Set-up & Cleaning

Spay

Neuter

Splenectomy

Voyant

Voyant Vessel Sealer

Please call 919-247-0328 if you have any questions.

1. Clamp the jaws on tissue

  • Squeeze latching handle to close jaws
  • Handle locks when fully compressed
  • Squeeze latching handle again to release jaws

2. Press and hold Fuse Activation Button to seal vessels. “Listen for beeps”

  • Generator will beep when sealing sequence is completed.
  • Large vessels may be sealed twice without cutting.

3. Slide Blade Lever trigger to cut

Voyant Vessel Sealer Cleaning Instructions

Please call 919-247-0328 if you have any questions.

NOTE:

Vessel sealing devices are considered disposable in the human medical market. In veterinary medicine it is acceptable to reuse the device after proper cleaning. Proper cleaning will greatly extend the life of the instrument.

  • Immediately after procedure, use a TEEZyme sponge to wipe the tip, jaws and shaft up to the black rotation ring.
  • The handle is not impervious. Wipe the handle with cloth or sponge dampened with water or alcohol.
  • Add water to provided tray. Squeeze rest of TEEZyme sponge solution into the water bath.
  • Immerse the tip of the instrument in the solution. Soak for 2-5 minutes.
  • DO NOT IMMERSE PLUG OR HANDLE (GREEN)
  • Use firm bristled brush to brush tip and jaws. Place tip of instrument into ultrasonic bath.
  • Rinse instrument in clear water and allow to dry.
  • Sterilize using EtO gas or Plasma sterilization. DO NOT AUTOCLAVE INSTRUMENTS.

Use a sponge and cleaning solution to wipe the tip, jaws and shaft up to the black rotation ring.

Immerse the tip of the instrument in the solution. Soak for 2-5 minutes.

Voyant Intelligent Energy System

The Voyant advanced bipolar system collects information about the nature of the tissue within its jaws, rapidly and constantly measures tissue as the energy is applied, and adjusts to provide the optimal amount of energy throughout the seal cycle to create a permanent, fused seal.

Leg amputation performed in a canine using the Voyant Fine Fusion device.

Splenectomy procedure performed in a canine with the Voyant Open Fusion device.

Device Key with Embedded Intelligence

  • Stores activation data to learn from live tissue.
  • Optimizes energy delivery for procedural and patient needs.
  • Enables efficient implementation of algorithm updates by delivering the most advanced technology with new handpieces.

Voyant Maryland Fusion

Voyant 5mm Fusion

Voyant Open Fusion

Voyant Fine Fusion

Laparoscopic Devices

Reorder No.DescriptionShaft Dimensions
EB210Voyant 5mm Fusion5mm x 37cm
EB211Voyant 5mm Fusion5mm x 44cm
EB215Voyant Maryland Fusion5mm x 37cm
EB216Voyant Maryland Fusion5mm x 44cm
EB217Voyant Maryland Fusion5mm x 23cm

Open Devices

Reorder No.DescriptionShaft/Device Length
EB230Voyant Fine Fusion19.3cm
EB240Voyant Open Fusion20cm

Generator

Reorder No.Description
EA020Voyant electrosurgical generator